To provide you with the best possible service, we make use of cookies. By accepting tracking cookies, you will be recognized. In that way, we can customize our website to your personal preferences and we can show you relevant information and advertisements on our website and others. If you agree, please click ‘I agree’. You can always view your settings and have them changed. For more information, see our cookie and privacy policy.

I agree

Mechanical seal piping plan 74

Description

Externally pressurised barrier gas supplied through a gas control system to a dual seal arrangement. An inert gas is used as a barrier gas.

Features

1. Media leakage to atmosphere is eliminated.
2. Obtain very high reliability, as solids or other materials, which can lead to premature seal failure cannot enter the seal faces.

Use

This plan is intended to be used for dual pressurised non-contacting gas seals.

1. Used in services which are not hot (within elastomer temperature limit) but which may contain toxic or hazardous material whose leakage to atmosphere can not be tolerated.
2. In case of solids or other material present in sealing media.
3. Where process contamination is allowed but process liquid leakage to atmosphere is not allowed.

Caution

1. Always ensure barrier gas pressure is higher than seal chamber pressure.
2. Causes media contamination due to high-pressure nitrogen entering the pump.
3. Pressure control valve should be set at least 1.7 bar greater than the seal chamber pressure.
4. Carefully consider the reliability of barrier pressure source, if central pressure issued.
5. Always check filter for any possible blockage.
6. Do not use for sticking or polymerizing media.

Duel gas seal plan 74

API pump seal plan 74 (Duel gas seal)

Uw browser is niet meer van deze tijd!