To provide you with the best possible service, we make use of cookies. By accepting tracking cookies, you will be recognized. In that way, we can customize our website to your personal preferences and we can show you relevant information and advertisements on our website and others. If you agree, please click ‘I agree’. You can always view your settings and have them changed. For more information, see our cookie and privacy policy.

I agree

Mechanical seal piping plan 23

Description

Product recirculation from seal chamber to heat exchanger and back to seal chamber.

Features

1. Circulation is maintained by pumping ring.
2. In idle condition heat transfer is maintained by thermosyphon effect and in running condition by a pumping ring.
3. Lower product stabilization temperature is achieved.
4. Establishes required margin between fluid vapour pressure and seal chamber pressure.

Use

1. In hot and clean services e.g. in boiler feed water and hot hydrocarbon services.

Caution

1. Maintain maximum 0.5m horizontal distance from seal chamber to heat exchanger.
2. Vent valve required at highest point of piping system.
3. Ensure that pump has a close clearance throat bush.
4. Ensure that the seal outlet connection is in the top half of the gland.
5. Ensure that the cooler is mounted above the pump centre line.
6. Vent the system fully before start up.

Single seal plan 23

API pump seal plan 23 (single seal)